Schwarzbeck Mess - Elektronik




Switch to: deutsche Version
Homepage    Contact    international representatives    Application Notes    Used Equipment    Search
AntennasAntenna Masts / Tripods / AdaptersCDN 0.15 - 230 MHz, IEC 1000-4-6, EN 61000-4-6
EMI-ReceiversHelmholtz Coils / Radiating LoopsAbsorbing clamps / braid current blocking Clamps
LISN Line Impedance Stabilisation NetworksNear field probesPulse Generators
Striplines / TEM-CellsAccessoriesDummy Lamps according to CISPR 15 EN55015
new Products

TypAccessories
VHIC 9260Antenna Impedance converter acc. CISPR 25 9 kHz - 30 (120) MHz.
VHIC 9260 Opt. ACS 110Option: Charger ACS 110 for VHIC 9260.
BD 9501IEEE-488 Bus-Feed through for flange mounting (shielded rooms) (other feed throughs on request)
HPFHigh Pass Filter 35 - 1000 MHz, Insertion loss at 27.12 MHz typ. 100 dB
CVP 9222High Impedance Capacitive Voltage Probe acc. to CISPR 22, EN 55022 C 1.3. Frequency range: 9 kHz – 100 MHz.
CVP 9222 Opt. ACS 110Option: Charger ACS 110 for CVP 9222.
CVP 9222 Opt. KAOption: Calibration Adapter for CVP 9222.
SW 9602Current Transformer, shielded, 0.01 - 200 MHz, Transfer Impedance: 1 Ohm for wires up to 6.5 mm.
SW 9603Current Transformer, shielded, 9 kHz - 150 MHz, Transfer Impedance: 1 Ohm for wires up to 14 mm.
SW 9605Current Transformer Clamp CISPR 22, 9 kHz - 80 MHz, Transfer Impedance: 1 Ohm for wires up to 23 mm.
SW 9606Current injection clamp for RF current injection into harnesses up to 23 mm diamter, transducer 18 dB.
SY 9501Balun unsymm. 50 Ohm to symm. 150 Ohm EN 55015, CISPR 15
[Picture]
SY 9223-CISPR 13Broad band isolation transformer acc. CISPR 13 fig. A.2, 50 Ohm 75 Ohm.
SY 9223-PLC1:1 PLC balun acc. to EN 50065-2-1 2003 + A1:2005 für Immunity against small band disturbance voltage. 3 kHz - 30 MHz, BNC and banana jacks.
Opt. 2 µF + 50 OhmOpt. for SY 9223-PLC: 2 µF + 50 Ohm, in isolated housing, banana jacks.
VTSD 9561 DDiode Pulse Limiter + 20 dB Attenuation, fuse lamp, BNC
VTSD 9561 FDiode Pulse Limiter + 10 dB Attenuation, fuse lamp, BNC
VTSD 9562Bandpass and Limiter for Partial Discharge Measurements BNC
BBV 9743Broadband Coaxial Preamplifier gain max. 30 dB, 10 MHz – 6 GHz, low noise floor, N-jack N-plug, including power supply.
BBV 9742Broadband Coaxial Preamplifier gain max. 30 dB, 9 kHz – 4 GHz, low noise floor, ESD protected, N-jack N-plug, including power supply.
BBV 9718Broadband Coaxial Preamplifier typ. 33 dB, 1 - 18 GHz with fixture for 22 mm
BBV 9718 Opt AkkuOption: Rechargeable battery pack for BBV 9718 or 9719.
[Picture]
BBV 9718 Opt. ALCS 2-24ABattery charger ALCS 2-24A for rechargeable battery pack
BBV 9718 Opt. PSOption: Power supply for BBV 9718 or 9719.
BBV 9719Broadband Coaxial Preamplifier typ. 33 dB, 18-26.5 GHz, power supply 12 V 300 mA necessary. Including short cable with SMA plugs to connect the BBV 9719 with the antenna (for example BBHA 9170).
BBV 9719 Opt. PSOption Power supply for BBV 9718 or 9719.
BBV 9719 Opt. BatteryOption Rechargeable battery pack for BBV 9718 or 9719
[Picture]
BBV 9719 Opt. ALCS 2-24ABattery charger ALCS 2-24A for rechargeable battery pack.
TF 130-150Test Fixture for Ford RI 130/ 150 Per EMC-CS-2009, newest version (REVISED: 11/11/2009).
VDHH 9502Van der Hoofden test head with protection network acc. IEC62493 or VDE 0848-493. Program for the calculation of F-factor
CISPR 17 EquipmentTransformers, fixtures and adapters to measure filters, ferrites and other passive components. Detailed product list and data sheets on request.
Coaxial Cables
AK 951350 Ohm Coax. Cable with N plugs, individual length, usable up to 3 (5) GHz. Indiv. Cal. possible if cable longer than 3 m. Standard lengths: 3 m, 5 m, 10 m.
AK 9515 D50 Ohm Coaxial Cable with N plugs, low loss, limited flexibility, usable up to 10 (18) GHz, 10.5 mm diam. Indiv. Cal. possible if cable longer than 1 m.
AK 9515 E50 Ohm Coaxial Cable with N plugs, low loss, good flexibility, usable up to 10 (18) GHz, 10.8 mm diam. Indiv. Cal. possible if cable longer than 1 m.
AK 9515 G50 Ohm Coaxial Cable available with N- or 7/16-plugs,very low loss, high power, good flexibility, usable up to 6 GHz, 14.6 mm diam. Indiv. Cal. possible if cable longer than 1 m.
AK 9515 H50 Ohm Microwave Coaxial Cable with N- or SMA connectors, low loss, flexible, usable up to 18 GHz. Indiv. Cal. possible if cable longer than 1 m.
MSS 9630Sheath current blocking cable to avoid coupling effects caused by braid currents. Standard configuration: N-male, N-female, length ca. 0.5 m
Fixed Attenuators
DGA 9552 NBidirectional Attenuator N-female N-male to 18 GHz, 50 Ohm 5 Watt. Available values: 3 dB, 6 dB, 10 dB, 20, 30, 40 dB.
Reference Radiators
SG 9301Spectrum Generator 30-1000 MHz, spectrum lines switchable 100 Hz – 1 MHz, N-female connector, charger 230 V AC, main application: reference radiator (antenna required e.g. UBAA 9114 with BBVU 9135)
SG 9302Comb generator 0.1 – 18 GHz, spectrum lines every 100 MHz, battery driven, including charger.
Field meters
VUFM 1670E-Field Meter 70 kHz-2.5 GHz, 1V/m-300V/m, linear polarized
VUFM 1671LCD-Display Unit for VUFM 1670 with 5 m fibre optical link
VUFM 1672LCD–Display Unit VUFM 1672 for E - Field-Meter VUFM 1670 with optical link and IEEE 488 / GPIB – Interface.