Radiating Loops

FESP 5410-1 - Square Induction Coil

FESP 5410-1 – Square Induction Coil

Usable Frequency Range: DC - 10 MHz

The square induction coil FESP 5410-1 is used to generate magnetic fields for immunity testing according to IEC 61000-4-8, IEC 61000-4-9 and IEC 61000-4-10. The side length of the square shaped coil is 1 m. The coil comes with screw terminals.

FESP 5139 - Radiating Loop (DC - 5 MHz)

FESP 5139 – Radiating Loop

Usable Frequency Range: 0 - 7 MHz

The magnetic, handheld coil FESP 5139 was designed to generate defined magnetic field strength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields. Depending on the current source char-acteristics magnetic fields up to 360 A/m can be generated for a short time.

Add to Quote
Schwarzbeck FESP 5133-9 - Circular Screened Coil

FESP 5133-9 – Circular Screened Coil

Usable Frequency Range: 10 kHz - 3 MHz

The magnetic, handheld coil FESP 5133 was designed to generate defined magnetic field strength in the audio frequency range up to 3 MHz. The main application is immunity testing against magnetic fields according to VG 95377 Part 13 and many others. Depending on the current source characteristics magnetic fields up to 400 A/m can be generated for a short time.

Add to Quote
Schwarzbeck FESP 5133-1330 Circular Radiating Loop

FESP 5133-1330 – Circular Coil

Usable Frequency Range: 0 – 20 (50) kHz

The handheld coil FESP 5133-1330 was designed for immunity testing against magnetic fields up to approx. 20 kHz. The coil has 225 turns of Cu-wire on 15 layers. There are spacers to provide a constant distance of 50 mm between coil center and EuT-surface. The generated magnetic fieldstrength is direct proportional to the coil current. Typical applications are Immunity Tests according to the Measuring Method SF 01 G acc. to VG 95377 standard.

Add to Quote
Schwarzbeck FESP 5135 Magnetic Loop

FESP 5135 – Circular Unshielded Coil

Usable Frequency Range: 0 - 300 kHz

The magnetic loop FESP 5135 was designed to generate magnetic fields in the frequency range up to 300 kHz. The FESP 5135 is especially used for magnetic immunity testing for large EuT which does not fit between Helmholtz coils. The FESP 5135 is equipped with spacers in order to achieve good repeatability of test results without using additional length measuring equipment.

Add to Quote
Schwarzbeck FESP 5133 Circular Screened Coil

FESP 5133 – Circular Screened Coil

Usable Frequency Range: 0 - 200 kHz

The magnetic, handheld coil FESP 5133 was designed to generate defined magnetic field strength in the audio frequency range up to 100 kHz. The main application is immunity testing against magnetic fields according to e.g. (of professional studio equipment acc. to EN 55103), MIL-STD 461, VG 95377 part 13) and many others). Depending on the current source characteristics magnetic fields up to 1000 A/m can be generated for a short time.

Add to Quote
FESP 5132 - Magnetic Handheld Coil

FESP 5132 – Radiating Loop

Usable Frequency Range: 0 – 150 kHz

The magnetic, handheld coil FESP 5132 was designed to generate defined magnetic fieldstrength in the audio frequency range up to 100 kHz. The main application is immunity testing against magnetic fields according to EN 55103 and MIL-STD-461 G. Depending on the current source characteristics magnetic fields up to 1500 A/m can be generated for a short time.

Add to Quote
Cable loop EN 303417 - Passive Magnetic TX Loop Antenna

Cable loop EN 303417 – Passive Magnetic TX Loop Antenna

Frequency range: 10 – 300 kHz, 6.765 – 6.795 MHz

The Cable loop EN 303417 is a passive loop antenna in the frequency range 10 300 kHz and 6.78 MHz. The antenna is used for the efficient generation of defined magnetic fields - for example when testing test specimens according to WPT standard EN 303417. The loop consists of a circular, flexible winding. with a diameter of 2 m. Loop has the capability to work broadband in the lower frequency range up to 300 kHz, but is resonantly tuned to 6.78 MHz.