This product has been discontinued. Datasheet SY 9223-PLC
SY 9223-PLC – 1:1 Broadband Balun
Never connect the SY 9223-PLC to 230 V AC mains directly. Always use isolation capacitors if connecting to mains. A suitable device would be IM 9223-PLC.
To measure radio frequency on the power-supply line an EMI-receiver or spectrum analyzer can be connected to the SY 9223-PLC instead of a signal generator. To protect the instruments against pulses or very strong signals, it is strongly recommended to connect an attenuator or pulse limiter between the measurement device and the SY 9223 PLC. VTSD 9561 D would be a suitable pulse limiter.
| Nominal frequency range: | 3 kHz – 30 MHz |
| Useable frequency range: | 1 kHz – 100 MHz |
| Attenuation (power) per balun: | max. 2 dB, typ. < 0.5 dB |
| Max. power: | 20 W |
| Voltage transformation: | 1:1 (0 dB) |
| Impedance transformation: | 1:1 |
| Inductance at low frequency: | ≅ 3.3 mH |
| Insulation strength prim.-sec. | >500 VAC |
| Weight: | 150 g |
| Coaxial connector: | BNC jack |
| Symmetrical terminals: | 4 mm laboratory jack |
| Connector to IN 9223-PLC (included within the scope of delivery of the SY 9223-PLC): | SCON-37 4 mm twin-plugs, 37 mm long |