TEMP 8400 – Tempest LISN 16A



It is constructed with air core inductors, in order to avoid intermodulation interference.
For the evaluation of interference phenomena the unsymmetrical interference voltage of a conductor to ground reference in the frequency range of 9 kHz to 1 GHz can be measured. Lower-frequency interference that may cause damage to the measuring receiver input shall be mitigated by additional high-pass filters.
| Frequency Range: | 9 kHz – 1 GHz |
| Max. cont. Current: | 16 A |
| Max. Current (limited time, 3 min): | 25 A |
| Max. Voltage (DC bis 400 Hz): | 250 V AC |
| Impedance (50Hz): | 1.4 Ω |
| AMN Impedance A or B: | (50 +/- 10) Ω |
| Insertion loss (EUT – AE): | Typ. 25 … 60 dB |
| Voltage Division Factor at the measuring port (EUT – Monitor): | (0 … -3) dB |
| EUT Connector: | N-female, Adapters available |
| Dimensions (W x H x D): | 448 x 191 x 470 mm |
| Weight: | 11.5 kg |