NNHV 8123-800 – Single path high voltage AMN (LISN)
The impedance characteristics are basically realized by connecting an inductor in parallel with the input impedance of the measurement receiver: 5 µH || 50 Ω.
The LISN has been designed to be installed into a shielded housing HVSE 8601 in pairs. Each NNHV 8123-800 can be used to measure one single path. To be able to measure HV+ and HV- 2 units are required. The device under test has to be connected to the terminal at the front panel. The supply voltage has to be connected at the back panel. The shield is connected to the HVSE 8601 feed through.
| Frequency range: | 0.1 – 150 MHz |
| Max. cont. current: | 500 A |
| Max. current (limited time) | 800 A |
| Max voltage (DC) | 1500 V |
| Max. voltage (AC 50/60 Hz): | 700 Vrms |
| Max. voltage (AC 400 Hz): | 300 Vrms |
| Impedance: | 5 µH || 50 Ω (+/- 10%) |
| DC-Resistance mains-EuT: | < 1.3 mΩ |
| Impedance (50 Hz): | 2 mΩ |
| Impedance (400 Hz): | 12.6 mΩ |
| EuT connectors: | screw terminal, see foto |
| Clamping range HV-cable: | 4 – 15 mm |
| Measuring port: | N-connector |
| Dimensions (W x H x D): | 226 x 241 x 407 mm |
| Weight: | 12.2 kg |



