VOLVO MagTest 1 MHz

Requires a MagTest Software version 1.4.3 or higher. Testing up to 200 kHz is done with Multimeters. Testing 200 kHz to 1 MHz is done with R&S RTE Oscilloscope. Oscilloscope should be kept at least 1m away from LFPA as GPIB communication may get influenced. Therefore one longer GPIB cable is offered.

SW 9605 - Current Clamp was designed to measure RF-currents.

SW 9605 – Current Clamp

Insertion Loss in 50 Ω System: 34 dB

The SW 9605 Current Clamp was designed to measure RF-currents on conductors or conductor bundles with a maximum diameter of 23 mm. The conversion ratio is 1:1 in the nominal frequency range, therefore the receiver-reading in dBµV corresponds directly to the current in dBµA.

Add to Quote
HHS 5206 – Circular Helmholtz Coils

HHS 5206-4 – Circular Helmholtz Coils

  • Number of turns: 4
  • Frequency Range: DC - 1.5 MHz
  • Coil Shape: Circular
  • Nominal Coil Current (continuous): 34 A
  • Maximum Coil Current (5 min.): 55 A
  • Magnetic Field Strength Nominal (continuos): 330 A/m
  • Magnetic Field Strength Maximum (5 min.): 530 A/m
  • Magnetic field strength at 1 A Coil Current: 9.64 A/m; 139.68 dBµA/m
  • Diameter/Side: 0.584 m
  • Resonance Frequency (pair of coils): 3000 kHz
Add to Quote
HHS 5205-1 - Circular Helmholtz Coils

HHS 5205-1 – Circular Helmholtz Coils

  • Number of turns: 1
  • Frequency Range: DC - 30 MHz
  • Coil Shape: Circular
  • Nominal Coil Current (continuous): 15 A
  • Maximum Coil Current (5 min.): 20 A
  • Magnetic Field Strength Nominal (continuos): 14.3 A/m
  • Magnetic Field Strength Maximum (5 min.): 28.6 A/m
  • Magnetic field strength at 1 A Coil Current: 1.43 A/m; 123.11 dBµA/m
  • Diameter/Side: 0.5 m
  • Resonance Frequency (pair of coils): 44000 kHz
Add to Quote
Schwarzbeck FESP 5133-9 - Circular Screened Coil

FESP 5133-9 – Circular Screened Coil

Usable Frequency Range: 10 kHz - 3 MHz

The magnetic, handheld coil FESP 5133 was designed to generate defined magnetic field strength in the audio frequency range up to 3 MHz. The main application is immunity testing against magnetic fields according to VG 95377 Part 13 and many others. Depending on the current source characteristics magnetic fields up to 400 A/m can be generated for a short time.

Add to Quote
HHS 5206 – Circular Helmholtz Coils

HHS 5206-16 – Circular Helmholtz Coils

  • Number of turns: 16
  • Frequency Range: DC - 500 kHz
  • Coil Shape: Circular
  • Nominal Coil Current (continuous): 33 A
  • Maximum Coil Current (5 min.): 55 A
  • Magnetic Field Strength Nominal (continuos): 1260 A/m
  • Magnetic Field Strength Maximum (5 min.): 2100 A/m
  • Magnetic field strength at 1 A Coil Current: 38.17 A/m; 151.63 dBµA/m
  • Diameter/Side: 0.6 m
  • Resonance Frequency (pair of coils): 700 kHz
Add to Quote
FESP 5132 - Magnetic Handheld Coil

FESP 5132 – Radiating Loop

Usable Frequency Range: 0 – 150 kHz

The magnetic, handheld coil FESP 5132 was designed to generate defined magnetic fieldstrength in the audio frequency range up to 100 kHz. The main application is immunity testing against magnetic fields according to EN 55103 and MIL-STD-461 G. Depending on the current source characteristics magnetic fields up to 1500 A/m can be generated for a short time.

Add to Quote